The hs code for hayward pool heaters is the classification number assigned to these products for international trade purposes. Hayward pool heaters fall under hs code 8419. Consequently, this code is used to facilitate smooth customs clearance and to ensure accurate tracking of imports and exports of these products globally.

Hayward heater hs code. There are quite a few Hayward pool heater error codes including the error codes AC, AO, bD, CE, EE, HF, HS, IF, IO, LO, PF, SB, SF, and bO. We will take a look at the meaning of all of them in our article and provide you with simple solutions.

Be the first to know. Email [email protected] to get notified. Enter the values in the highlighted cells paying attention to the units, For a 5mph wind, add 25%. For a 10 mph, double the kW required.

I have a new Hayward heater. I keep getting a lo code when the pool is turned off. This is a brand new heater and pool. My pool company that installed the pool told me to make sure I'm getting proper water flow in the system. But didn't tell me how to do this. Do I do it on the Hayward...Problem Possible Cause Possible Solution; Heater cycles on & off: 1. Filter or pump baskets are dirty. 2. External bypass is out of adjustment. 3. Internal bypass is broken or stuck.LO CODE FIXES. Step 1: Inspecting the Water Pressure Switch Wiring. Step 2: Testing Water Pressure Switch Continuity. Step 3: Pressure Switch Adjustment (If Required) Step 4: Temperature Limit Switch Wiring Inspection. Step 5: Continuity Test for Temperature Limit Switches.This is usually in your home's main electrical panel. Flip the breaker for your pool heater to the "Off" position, wait a few seconds, then flip it back to the "On" position. Finally, power your heater back on using the power switch. After a successful reset, your heater should be functioning correctly.84193210-dryers-for. 84193250-dryers-for-paper-pulp-paper-or. 84193901-dryers-other-than-of-a-kind-for-domestic. 84219120-drying-chambers-for-the-clothes-dryers-of. heater for dryer HS-codes.com is specialize in providing harmonized tariff numbers and commodity codes. Visit us online to get the various hs codes and commodity description.Manifold Gas Pressure. 7.0". Maximum inlet gas pressure 13.0". SAMPLE. Minimum inlet gas pressure. 10.0". Using a Manometer, take a measurement at the inlet port on the gas valve for both Static Pressure (heater o ) & Load Pressure (heater red); readings should be within the values on the heater data plate. Then measure the Manifold ...The Hayward HeatPro 140K Electric Heat Pump is a high-efficiency heater, gives you the ideal water temperature while using 80% less energy than natural gas heaters. It offers an alternative way to heat your pool that is safe, reliable, and energy efficient. Hayward HeatPro Electric Heater takes the heat from the surrounding air and uses it to ...You need to put the heater in STANDBY Mode to get the bO code on the heater display. Press the mode button once to get the heater in STANDBY Mode. First, press and hold on to the Down key. Then, press and hold down the MODE key as well. You need to keep holding both keys for about three seconds. At this point, the “bO” message should appear ...

The Universal H-Series 200,000 BTU Propane Gas Pool & Spa Heater from Hayward provides reliable, long-lasting comfort for pools and spas with a surface area of up to 600 ft. Built with a durable cupro nickel heat exchanger, it offers exceptional protection against corrosion and premature failure caused by unbalanced water chemistry, ensuring ...To fix the issue of your OmniLogic losing connection, try these steps: 1) Turn off power at the breaker. 2) Turn the power back on and let the system reboot. This simple power cycle should reconnect the system to the Wi-Fi network. It may also be caused by wireless interference or a weak signal from your router. For hayward pool heater if code repair, check the pressure switch and ensure proper pressure is being reached. Hayward pool heaters display an “if” code when the pressure switch is not closed. This is caused by insufficient water flow, closed valves, air in the system, or a clogged filter. It is important to identify and fix the issue ... Common Causes of the H5 Code. When your pool heater displays the H5 code, it typically occurs due to a few common reasons. Troubleshooting h5 code in other pool equipment can help identify the issue. Common misconceptions about h5 code in Hayward pool heaters include thinking it is solely related to a faulty igniter or gas valve.The Hayward Universal H-Series gas heater is the "universal" energy efficient remedy for any new or existing pool or spa. An industry leading hydraulic design reduces circulation pump run time to provide energy savings of up to 18% when compared to less efficient competitors. ... South Coast Quality Air Management Commission for 2001 and the ...Dec 30, 2021 · Critter ruins the control circuits of a pool heater.In this case, we needed to swap out the display board and the Control board. Pool and Spa Expert: CertifiedPoolPro. Yes on actual heater it is left on spa or pool does not matter which one because the control now comes from automation. Temperature at the actual heater should be set to max as well. Again because temperature setting will come from automation not heater. Ask Your Own Pool and Spa Question.

Hayward Universal HC Series Dual-Fuel HDF400 Technology Gas Heater Thermistor| FDXLTER1931. $49.99. ... Code: Description: Information: AC: ... HS: High temperature sensing error: A) Inlet water temperature sensor is reporting a temperature in excess of 104°F. Normal operation resumes 2 minutes after inlet water temperature sensor reports ...Mar 16, 2018. #1. We have a Hayward H400IDL2 pool heater that ignites and runs normally at start up. After about 10 minutes it begins to repeatedly cycle off and on before finally throwing an IF code. We've had multiple service calls from 2 different pool companies and have replaced the gas valve, flame sensor, igniter and control board.Carefully check over the pump impeller, diffuser, shaft seal, and motor for problems or signs of damage, and replace parts as necessary. Verify motor connections to the drive. Heatsink Overheated. The heatsink of the drive has overheated. Make sure that the vents on the motor are clear of debris and obstructions.Go Green with a little help from the sun. AquaSolar GL-235™ is America's best-selling entry level microprocessor based solar pool heating control system designed for easy and dependable operation. Enjoy automatic maximization of solar heat collection and reliable, accurate performance. AquaSolar GL-235 also includes a nocturnal cooling option.

Gillette water park.

my hayward heater keeps going off ..... pump pressure is at 14#'s. just setup filter and heater. the code is HS. Is it a bad water temp sensor … read moreView and Download Hayward H250FDN service & installation manual online. POOL AND SPA/HOT TUB HEATERS. H250FDN heater pdf manual download. Also for: H250fdp, H350fdn, H350fdp, H400fdn, H400fdp.Step 1 Step 2 Verify the heater's power LED is illuminated, and put the heater is Using the up and down arrows adjust the heater to the desired the desired mode. Page 13 How To: Set Clock Follow these steps to adjust the Clock Settings. Note: blocked off areas of the display represent flashing numbers.Here are some of the best outdoor heaters for restaurants to keep your customers warm and cozy when they want to dine outdoors to enjoy a meal. If you buy something through our lin...

View online or download PDF (6 MB) Hayward H250FD, H350FD, H300FD, H150FD, H400FD, H200FD, Universal H-Series Low NOx User manual • H250FD, H350FD, H300FD, H150FD, H400FD, H200FD, Universal H-Series Low NOx above ground pool accessories PDF manual download and more Hayward online manuals.May 10, 2022 · Step 5: Clean the filter or remove any obstructions. Examine the position of the valves in the plumbing system. Set the water pressure switch to the desired setting. If the Hayward pool heater LO code persists, the water pressure switch must be replaced. I have a Hayward 135k pool heater that I just installed. I have an HS code on the display. It runs for about 1 minute then displays this code. The temp starts at 50 degrees and climbs rapidly to 56 th … read moreView online or download Hayward H200FDN Troubleshooting Manual. ... Brands; Hayward Manuals; Heater; H200FDN; Hayward H200FDN Manuals. Manuals and User Guides for Hayward H200FDN. We have 2 Hayward H200FDN manuals available for free PDF download: Troubleshooting ... SF" or "HS" Code. 40. PF" Code. 42. HF" Code. 44. LO" Code. 46. Pressure Switch ...Conclusion. In conclusion, troubleshooting the Hayward pool heater code 1F can be done by following a few simple steps. First, check the water flow to ensure there aren't any blockages or restrictions. Next, inspect the pressure switch for any signs of damage or malfunction. If necessary, clean the heat exchanger to remove any debris or buildup.code serial number over all I wish that I could send you a short video.it is blinking this. the blink is a fast random blink. it was installed in 2013 and has been working fine. yesterday I went to get in the hot tub for the first time this season. so when I turned on the breaker, this is what I got.almost looks like it is trying to power up. but I don't know. did those photos come across okay?Check your filter pressure differential and skimmer baskets. With variable speed pumps, ensure you have the RPM of the filter pump set at 2200 RPM. Check and clean the heaters' heat exchanger. Remove and inspect the High limit sensors, and there are two located in the header of the heater.I have a Hayward Pro Heat pump HP13023646 it is 11 months old. Started pool up yesterday, and it fired right up. a few minutes later the code "HP" appeared. the unit shut down for a few seconds and started back up. it runs... you hear it kick in for a few seconds to a minute and then this shut down start up repeats.hayward pool heater H-350 codes SF & HS. Would like to know. hayward pool heater H-350 codes SF & HS. Would like to know how to test temp sensor. I have 15 volts on all 3 wires at control panel ...

Jan 1, 2024 · Common Causes of the H5 Code. When your pool heater displays the H5 code, it typically occurs due to a few common reasons. Troubleshooting h5 code in other pool equipment can help identify the issue. Common misconceptions about h5 code in Hayward pool heaters include thinking it is solely related to a faulty igniter or gas valve.

For hayward pool heater if code repair, check the pressure switch and ensure proper pressure is being reached. Hayward pool heaters display an “if” code when the pressure switch is not closed. This is caused by insufficient water flow, closed valves, air in the system, or a clogged filter. It is important to identify and fix the issue ...How to Build a Easy DIY Solar Pool Heater. All you need is 4 two foot lengths of pvc, 4 90 degree pvc elbows, foam pipe insulation, duct tape, 6 mil black plastic and some wire ties.My Hayward spa heater (installed 2018) is not heating the water and is displaying this LO code. I have read every troubleshooting guide and watched every video I could find. My diagnostics included: 1. Cleaned the filters, even ran the pump without the filters - still LO 2. Checked wires at pressure switch for continuity - still LO 3.Facts in Brief. Electric Water Heater worth $55,793,791 under HS Code 85161000 have been imported. Average import price for electric water heater under HS Code 85161000 was $46.21. Please use filters at the bottom of the page to view and select unit type. You may also use the analysis page to view month wise price information.Jul 21, 2013 47,820 Northern NJ Pool Size 35000 Surface Plaster Chlorine Salt Water Generator SWG Type Pentair Intellichlor IC-60I have a Hayward 135k pool heater that I just installed. I have an HS code on the display. It runs for about 1 minute then displays this code. The temp starts at 50 degrees and climbs rapidly to 56 th … read moreStumbling upon a 'LO' code on your Hayward heater can be quite the head-scratcher. Don't worry, you're about to unravel the mystery behind this cryptic message. This code typically indicates a water temperature sensor error, but it can also be a sign of other underlying issues with your pool heater. In this article, you'll learn the steps to diagnose and fix the problem, ensuring your pool remainsWelcome to Hayward Rebates! copyright © 2020 hayward industries, inc ACB Privacy Statement Remove front & rear panels Remove wires from limit switches. Step 13. Remove the 4 screws from the bottom of the front and rear panels and pull up and out to remove each one. Step 14. Use needle nose pliers to remove the 2 red wires from each of the high limit switches. Remove wires from water pressure switch.

French door seating chart.

How to put 2 stamps on an envelope.

Heater will not power up. Open FC1 and/or FC2 Fuse. Open FC3 and/or F1 Fuse. Open FC4 Fuse. Diagnostic Codes. Page 1. Pages 2-3. Pages 4-5. Pages 6-7. Pages 8-9. Page 10. Page 11. Page 12. Pages 13-20. Pages 21-22. Pages 23-26. Pages 27-28 . Page 29. BD Code. EE and CE Codes. IO and SB Codes. SF and HS Codes. HE and PF Codes. HF Code. LO Code ...2. Friendswood/Texas. Nov 18, 2015. #1. I recently had a problem with our Hayward H250IDL2 heater. It showed an "IF" code, which stands for Ignition Failure. I do my own maintenance when I am able to, so I pulled the covers off of the unit and started trouble shooting. I did not manage to resolve the problem, so I called my local pool service ...The defective connection or improper wiring of the Hayward heater control module is another reason for which your heater displays the CE code. The heater's control module automates and controls the ventilation and heating operation. ... Some people mistake the H5 code on their Hayward heater, but really it's the HS code on a Hayward heater ...Super common. It is always a good idea to have a pool heater serviced in the Spring by a gas tech. Most guys charge ~$150 to do a full clean up by removing the burner tray and clearing out the spider nests, dust, and debris that accumulated over the Winter months of no use.The Hayward HeatPro 140K Electric Heat Pump is a high-efficiency heater, gives you the ideal water temperature while using 80% less energy than natural gas heaters. It offers an alternative way to heat your pool that is safe, reliable, and energy efficient. Hayward HeatPro Electric Heater takes the heat from the surrounding air and uses it to ...Dealing with the Hayward Heater HS IO code can be challenging, but with the right knowledge, preventive measures, and a willingness to explore advanced options, you can maintain a reliable and safe heating system for your pool or spa. Remember that safety should always be a top priority when working with gas appliances, and don't hesitate to ...IF NOT, open gas supply. Flame sensor & gas valve Step 12C Verify that the gas valve, inside the heater, is ; Hayward H400FDP | Universal H Series Troubleshooting Guide - Page 55 12. Service LED ON: "IF" Code (cont.) Voltage/pressure off gas valve Step 12E Verify correct flame sensor Step 12F Verify 22-28VAC off gas valve during ignition trial.Dec 30, 2021 · Critter ruins the control circuits of a pool heater.In this case, we needed to swap out the display board and the Control board. HSN Code. Product Description. 8419. Machinery, plant or laboratory equipment, whether or not electrically heated, (excluding furnaces, ovens and otherequipment of heading 8514), for the treatment of materials by a process involving a change of temperature such as heating, cooking, roasting, distilling, rectifying, sterilising pasteurising ...If you're looking for help fixing your Hayward Pool Heaters, look no further! Our comprehensive Hayward Pool Heaters error code guide will explain common iss...For people using gas water heaters, two options are offered--natural gas or propane. According to Energy Star, 15 percent of a home’s energy use is attributed to heating water. Bot... ….

Hayward pool heater H-350 codes SF & HS. Would like to know how to test temp sensor. I have 15 volts on all 3 wires - Answered by a verified Pool and Spa Expert. ... pump pressure is at 14#'s. just setup filter and heater. the code is HS. Is it a bad water temp sensor ...May 23, 2017 ... HS code exists telling thou that the water output temp is too high. The code does not necessarily mean the sensor is bad but, the instead say ...My hayward heater is showing a CE code. I've replaced the display and ignition boards and it's still showing a CE - Answered by a verified Pool and Spa Expert We use cookies to give you the best possible experience on our website. Universal H-Series Natural Gas 400,000 BTU Low NOx. Hayward. SKU: W3H400FDN. The Universal H-Series is an energy efficient, high performance, installation adaptable commitment to the pool service professional. Add to Compare. Add to Export. 1-16 of 921 results for "Hayward Pool Heaters" Results. Hayward. W3H400FDN Universal H-Series 400,000 BTU Natural Gas Pool and Spa Heater for In-Ground Pools and Spas ... Bezel and Keypad Assembly Replacement Kit # FDXLBKP1930 Replacement for Hayward Compatible with Universal H-Series Low NOX Pool Heater Fits Models H150FDN, H150FDP,H300FDN ...Universal H Series Heaters® Troubleshooting: Hayward H400FDN | Universal H Series Troubleshooting Guide - Page 19 Diagnostic Codes Below is a list of all Diagnostic Codes for the UHS Heater. Troubleshooting Steps for each Code are covered on the following pages. Diagnostic Code AC AO BD CE EE HF HS IF IO LO PF SB SFHayward FDXLBKP1930 Bezel and Keypad Assembly Replacement Kit for Hayward Universal H-Series Low Nox Pool Heater 4.5 out of 5 stars 784 11 offers from $75.00Hayward H-Series Integrated Control Board | FDXLICB1930 For H150FD/H200FD/H250FD/H300FD/H350FD/H400FD Universal H-Series Low NOx and Pool and Spa/Hot Tub HeatersHayward pool heater turns on and than right off. Postby Me... » Sat 28 Feb, 2009 00:27. You might have an issue with your venting or exchanger being at least partially blocked. If the heater can't get rid of the products of combustion, excess heat and/or flames etc will roll out the bottom by the burner tray. There is a safety switch that …The heater must be installed such that the location of the exhaust gas vent assembly outlet relative to adjacent public walkways, adjacent buildings, openable windows, and building openings complies with the National Fuel Gas Code (ANSI Z223 ; Hayward HDF400 | HDF400 User Manual - Page 13 heater may be installed on either non-combustible heater. Hayward heater hs code, Hayward Pool Products Inc is a leading manufacturer of high-quality pool equipment, including pumps, filters, heaters, and cleaners. If you’re lucky enough to own one of their prod..., 1.3 Heater Cycling On And Off. 2 Troubleshooting Steps. 2.1 Check Gas Pressure And Fuel Supply. 2.2 Inspect Air Supply And Venting. 2.3 Ensure Proper Water Flow. 2.4 Clean Filters And Pump. 2.5 Adjust External Bypass If Needed. 3 Tips For Diagnosing Problems. 3.1 Follow The Heater Start Sequence., A common problem with the Pentair pool heater is that the display doesn't work. This issue often occurs when there is a problem with the display board or the controller fuse., HTS Code: 8516.29.0060 - Electric Portable Space Heaters, Others - Saw imports of $ 4,510,158 and exports of $ 0 in Jul. This is a change of -16.70% and 100% respectively from the month Jul of 2019. This data is derived from Datamyne, using US import and export trade data released by the US Census Bureau in the Merchandise Trade dataset ..., HeatPro Heat Pump 140k BTU. Hayward. SKU: HP21404TC. High performance, energy-efficient HeatPro heat pumps quietly and economically maintain the ideal water temperature at all times. Add to Compare. Add to Export. Overview. Specifications., View online or download Hayward HDF275 Troubleshooting Manual. ... Hayward Manuals; Heater; HDF275; Hayward HDF275 Manuals. Manuals and User Guides for Hayward HDF275. We have 1 Hayward HDF275 manual available for free PDF download: Troubleshooting ... SF" or "HS" Code. 41. PF" Code. 42. HF" Code. 43. LO: Code. 44. IF" Code. 48. AC" Code. 50 ..., By clicking "Find Related HS Code" button above, you can find 6 digits universal HS Code (which is valid for almost all countries in the world) and declarable codes for EU, UK, USA, Japan, China, India and Turkey (e.g. 10 digits TARIC code for EU countries or HTSUS code for USA) of "portable space heaters". You can also find customs duty rates ..., As the World's Foremost Outfitter of Hunting, Fishing and Outdoor gear, Cabela's offers over 150,000 top-quality products to enhance any outing. In addition to a huge selection of catalogs and an industry leading website, the large destination Retail showrooms offer a retail experience like no other!, The Universal H-Series Low NOx heater has an 84 percent industry-leading thermal efficiency and complies with all current California air quality emission standards. The low NOx emission makes it a perfect choice for the environmentally concerned pool owner. Enjoy a warmer pool this season without your fuel costs skyrocketing., The codes indicate specific issues that need to be addressed to get the heater running again. By knowing what each code means, you can identify the problem and find a solution more quickly., A Hayward pool heater heat exchanger leaking is a common problem. Pool owners should check the water level in the filter, clean debris from the unit and inspect for leaks around fittings or valves. If there are cracks or holes in the heat exchanger, then it needs to be replaced as soon as possible. The best way to fix this issue is by draining ..., Hayward Heater IF Code. Hello, I would appreciate any guidance that anyone may have to share. We are attempting to start up our Hayward heater for the season, but getting an IF code. Power is on, gas is on, pool water is flowing. I can hear the heater try and run for a few minutes, then a click and a restart. Eventually it gives us the IF code., Clean the hayward heater regularly to prevent any debris buildup, which can trigger the if code. Remove leaves, sticks, and other objects from the heater. Check the air filter and clean or replace it as needed. A dirty filter restricts airflow and can cause the heater to overheat, resulting in the if code., Common Causes of the H5 Code. When your pool heater displays the H5 code, it typically occurs due to a few common reasons. Troubleshooting h5 code in other pool equipment can help identify the issue. Common misconceptions about h5 code in Hayward pool heaters include thinking it is solely related to a faulty igniter or gas valve., Search Electrical heater HS Code for Electrical heater import and export at seair.co.in. We also provide Electrical heater import data and Electrical heater export data with shipment details. +91 9990837766 [email protected] Enquire Now ..., I have a Hayward 135k pool heater that I just installed. I have an HS code on the display. It runs for about 1 minute then displays this code. The temp starts at 50 degrees and climbs rapidly to 56 th … read more, HS Code 85162950 - Electric, convection, heaters. Can be used for an export declaration. 1. Electric convection heater for space-heating, 1500 watts, 12x12x6 inches. 2. Electric convection heater for soil-heating, 2000 watts, 15x10x8 inches. 3., Page 1 POOL AND SPA/HOT TUB HEATERS H135ID & ABG135 MODELS SERVICE & INSTALLATION MANUAL Unit must be installed outdoors only and below an altitude of 2000 feet FOR YOUR SAFETY WARNING: If the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, injury, or death., The Hayward heater LED display will show a diagnostic fault code of "IF" which stands for Ignition Failure. Why choose Hayward H-series pool heaters?. The Universal H-Series 150,000 BTU Natural Gas Pool & Spa Heater from Hayward provides reliable, long-lasting comfort for pools and spas with a surface area of 400 ft., Search Results related to hayward heat pro error codes on Search Engine. © 2017 Websiteperu.com. All Rights Reserved, The Hayward heater LO code indicates a fault in the temperature limit switch, vent pressure switch, or water pressure switch. To fix it, ensure the pump is on, is wired and connected well, the water flow is above the required minimum pressure, the filters are clean. ... High readings may indicate a blockage, a common culprit behind the LO …, Sep 10, 2023 · Always refer to the user manual or consult a professional if you are unsure about the corrective actions required to address the high salt warning on your hayward pool heater. What Is The Hs Code For Pool Heater? The hs code for pool heaters is 8419. 50. 50. Pool heaters are categorized under this specific hs code for international trade purposes. , Hayward Universal H-Series Low NOx Induced Draft Pool & Spa Heater | 400,000 BTU | Natural Gas | W3H400FDN. The Hayward Universal H-Series gas heater is the "universal" energy efficient remedy for any new or existing pool or spa. An industry leading hydraulic design reduces circulation pump run time to provide energy savings of up to 18% when ..., Here you'll gain easy access to information regarding your favorite Hayward products. Whether you are looking for a Quick Reference Guide, troubleshooting steps, or simply wish to view one of our product support videos, you have come to the right place. ... Universal H Series and ASME Gas Heater Installation, Start-up and Troubleshooting ..., Models manufactured before Sept. 2010: measure across pins 1-2 (black & red), then 3-4 (white & blue) for 8-9 ohms. Models after Sept. 2010: measure for 4-5 ohms across the two terminal with wires. IF out-of-range, replace blower (pg. 20). IF correct, contact technical support (908)355-7995., Check your filter pressure differential and skimmer baskets. With variable speed pumps, ensure you have the RPM of the filter pump set at 2200 RPM. Check and clean the heaters' heat exchanger. Remove and inspect the High limit sensors, and there are two located in the header of the heater., Remove front & rear panels Remove wires from limit switches. Step 13. Remove the 4 screws from the bottom of the front and rear panels and pull up and out to remove each one. Step 14. Use needle nose pliers to remove the 2 red wires from each of the high limit switches. Remove wires from water pressure switch., The best pools start with hayward. #1 Products brand amongst pool professionals. 95+ Years in business, advancing pool equipment & technology. 2k Innovative team members committed to transforming the experience of water. About us Join our team., Diagnostic Codes For Hayward Heat Pump, Hayward pool heater H-350 codes SF & HS. Would like to know how to test temp sensor. I have 15 volts on all 3 wires - Answered by a verified Pool and Spa Expert, The Universal H-Series is an energy efficient, high performance, ... Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. ... Phase Heaters: 1.0000: Pool Type: In Ground: Product Dimensions: 24 " x 19 " x 29.5 "Product Height: 24 in: Product Length: 29.5 in ..., Jul 3, 2022 · I have a Hayward 135k pool heater that I just installed. I have an HS code on the display. It runs for about 1 minute then displays this code. The temp starts at 50 degrees and climbs rapidly to 56 th … read more , Exiting Bypass Operation. To exit bypass operation and resolve the bO Code problem, follow these steps: First, set the heater to standby mode. Next, press and hold the Down key and MODE key for three seconds. Finally, verify that the display no longer shows the "bO" indication.