Please call 855-565-6722. This online training can take up to to 4 hours and covers the highlights and most recent changes required by OSHA 1926.32 (f), 1926.500 and 1910 fall protection standards. Course highlights include work applications and scenarios as well as new regulatory and fall protection product developments. EM385-1 Online ...

Em385. EM 385-1-1 (July 2014) 01.A.14 Contractor Risk Management Process (AHAs) b. Before beginning each work activity, task or (DFOW), the Contractor performing that work activity shall prepare the initial AHA. A Risk Assessment Code (RAC) is assigned to each step, to the risk that remains after controls have been applied (residual risk).

EM 385-1-1 XX Jul 14 5-2 b. When the employer has reason to believe that any affected employee who has been trained does not have the understanding and skill required for …

EM 385-1-1 30 Nov 14 9-3 09.A.11 Measures must be taken to control the growth of tall grass, brush, and weeds adjacent to facilities. A break of at least 3 ft (0.9 m) shall be maintained around all facilities. 09.A.12 Paint-soiled clothing and drop cloths, when not in use, shall be stored in well-ventilated steel cabinets or containers. 09.A.EM 385-1-1 (2024 Edition) 12-Hour Refresher Online. We offer a 40-Hour (2014 Edition) and 12-Hour Refresher (2024 Edition) course for EM 385-1-1 required for US Army Corps of Engineers Safety and Health Requirements which upon the completion of this course, you will receive an EM 385-1-1 certificate that is valid for 5 years.EM 385-1-1, Safety and Health Requirements Manual. You can download a copy of the Complete EM 385-1-1, 2014 Version or it can be accessed through the USACE Official …EM 385-1-1 XX Jul 14 1-2 01.A.07 SOH Bulletin Board. The Contractor or USACE Project shall erect and maintain a SOH bulletin board in a commonly accessed area in clear view of the on-site workers. The bulletin board shall be continually maintained and updated and placed in a location that is protected against the elements and unauthorized removal.This manual (EM 385-1-1) includes changes 1-6 as of 05 July 11. The manual describes safety and health requirements for all Corps of Engineers activities and operations, including Naval Facilities Engineering …EM 385-1-1 XX Jul 14 5-2 b. When the employer has reason to believe that any affected employee who has been trained does not have the understanding and skill required for …EM 385-1-1 30 Nov 14 9-3 09.A.11 Measures must be taken to control the growth of tall grass, brush, and weeds adjacent to facilities. A break of at least 3 ft (0.9 m) shall be maintained around all facilities. 09.A.12 Paint-soiled clothing and drop cloths, when not in use, shall be stored in well-ventilated steel cabinets or containers. 09.A.8-Hour EM 385-1-1 Refresher Training. The 8-Hour EM 385-1-1 online refresher course is designed to keep Site Safety Health Officers (SSHOs), military contractors and government employees compliant with annual refresher training requirements from the U.S. Army Corps of Engineers. $99.

L6385cons. Subchefia para Assuntos Jurídicos. LEI No 6.385, DE 7 DE DEZEMBRO DE 1976. Texto compilado. Mensagem de veto. (Vide Decreto-lei nº 2.064, de 1983) (Vide Decreto-lei nº 2.065, de 1983) (Vide Decreto-lei nº 2.286, de 1986) (Vide Decreto nº 91.152, de 1985) Dispõe sobre o mercado de valores mobiliários e cria a Comissão de ...The EM 385-1-1 manual was designed by USACE, in collaboration with NAVFAC, and provides an overview of the safety requirements on federal projects. The 2014 Edition supersedes the last edition of EM 385-1-1 published in 2008. While many of the requirements in the EM 385-1-1 align with OSHA Standards, some specific requirements …May 6, 2015 · Many changes were made to the 2008 edition of the EM and have been identified in the 2014 text by "underlining". Remember, underlining of text in the EM itself identifies changes from the 2008 EM 385-1-1 (and its seven published changes). Acknowledge the risks and assign a Risk Assessment Code (RAC). Review every hazard and assess the risk in terms of: Probability – frequent, likely, occasional, seldom or unlikely. Severity – catastrophic, critical, marginal or negligible. Use the RAC matrix on EM 385-1-1 to assess the hazards and determine the overall risk assessment … EM 385-1-1 30 Nov 14 1-3 b. The current Unified Facilities Guide Specification (UFGS) for Safety and Health in effect on the date of solicitation shall be used in all USACE contract work administered on behalf of the USACE under the provisions of FAR Clause 52.236-13 Apr 12, 2024 · The revised EM 385-1-1 manual brings several significant changes aimed at enhancing safety and streamlining procedures. Here are some key highlights: Streamlined Structure: Gone are the days of navigating through a maze of information. The new manual is reorganized into 37 focused chapters, each dedicated to a specific safety topic. EM 385-1-1 30 Nov 14. 24-12 b. Carabiners and snap hooks: Used for climbing (life support) shall have at least two consecutive, deliberate actions to prepare the gate for opening and shall be rated at 5,000 lbs (22.2kN) and shall meet the ANSI/ASSE Z359 Fall Protection Code. Gates shall be rated at 3600 lbs (16kN).

EM-385 is the code for the safety and health requirements written and constantly updated by the US Corps of Engineers and is meant to regulate DoD projects. This manual very much resembles OSHA, which should not come as a surprise, since both codes are meant to promote occupational health and safety. For instance, both OSHA and EM-385 require ... EM 385-1-1 (July 2014) 01.A.14 Contractor Risk Management Process (AHAs) b. Before beginning each work activity, task or (DFOW), the Contractor performing that work activity shall prepare the initial AHA. A Risk Assessment Code (RAC) is assigned to each step, to the risk that remains after controls have been applied (residual risk). provide policy, programs, technical services, oversight and outreach related to safety and occupational health matters in support of USACE missions worldwide. EM 385-1-1 - Army Corps of Engineers Safety and Health Requirements Documents. Engineering Manual (EM) 385-1-1 is a comprehensive set of safety and health standards required for all operations that services and operations that are subject to OSHA's construction standard (29 CFR 1926.11). in conjunction with ER 385-1-80 and EM 385-1-1. Contractor requirements concerning ionizing and non-ionizing radiation protection issues are contained in EM 385-1-1. 1-3. Distribution Statement. Approved for public release; distribution is unlimited. 1-4. References. Appendix A contains a list of references used in this manual. 1-5. Policy. a.

Den to phl.

The EM 385-1-1 manual was designed by USACE, in collaboration with NAVFAC, and provides an overview of the safety requirements on federal projects. The 2014 Edition supersedes the last edition of EM 385-1-1 published in 2008. While many of the requirements in the EM 385-1-1 align with OSHA Standards, some specific requirements …EM 385-1-1 XX Jul 14 33-2 c. Hazardous waste operations performed by Government personnel do not require development of an APP, but do require a Project Safety and Health Plan and a SSHP in compliance with Section 01.A.09 and local safety and health policies for in-house activities. All activities shall comply with the written SSHP. EM 385-1-1 XX Jul 14 5-1 SECTION 5 . Personal Protective and Safety Equipment . 05.A General Requirements. 05.A.01 Responsibilities. a. The use of personal protective and safety equipment (PPE) is a control measure that is to be used only after a hazard evaluation identifies hazards associated EM 385-1-1 XX Jul 14 16-2 g. Machinery that hoists by using a come-a-long or chainfall (whether human-, air- or electric- powered, chain or wire-rope type); h. Operators of equipment with a maximum manufacturer-rated hoisting/lifting capacity of 2,000 pounds (907 kg) or less, are exempt from the operator qualification ormust be familiar with the requirements of EM 385-1-1 and have experience in the areas of hazard identification and safety compliance. The individual must be capable of interpreting a critical path schedule and construction drawings. The qualification requirements for the alternate superintendent are the same as for the project superintendent. TheApr 12, 2024 · The revised EM 385-1-1 manual brings several significant changes aimed at enhancing safety and streamlining procedures. Here are some key highlights: Streamlined Structure: Gone are the days of navigating through a maze of information. The new manual is reorganized into 37 focused chapters, each dedicated to a specific safety topic.

What is EM 385-1-1 Training? If you are a contractor working on military projects, you must familiarize yourself with the U.S. Army Corps of Engineers Safety and Health …ArmyArmyEM 385-1-1 30 Nov 14 23-5 g. Where material is dumped from mechanical equipment or wheelbarrows, a toe board or bumper, not less than 4 in (10 cm) thick and 6 in (15 cm) high, shall be attached at each chute opening. h. Chutes shall be designed and constructed of such strength as to eliminate failure due to impact of materials or debris loaded ... EM 385-1-1 30 Nov 14 16-2 h. Operators of equipment with a maximum manufacturer -rated hoisting/lifting capacity of 2,000 pounds (907 kg) or less, are exempt from the operator qualification or certification requirements in Sections 16.B.02 through 16.B.05 only. In addition, this equipment may not be used to hoist personnel ; i. What is EM 385 fall protection competent person training? EM 385 is the Engineer’s Manual released by the U.S. Army Corps of Engineers outlining the health and safety standards …EM 385-1-1 (2014) Contractor Safety. OSHA definitions changed for Confined Space in construction. 01.A.12 Accident Prevention Plan (APP) for Contract Work. Before initiation …入札公告日に有効な、em 385--1 1の最新版 (暫定的な変更を含む) を遵守しなければならない。 応札の前に入札者は、hqusace の労働安全衛生ウェブサイト (c. 参照) で、最新の変更点を確 認すべきである。

Many changes were made to the 2008 edition of the EM and have been identified in the 2014 text by "underlining". Remember, underlining of text in the EM itself identifies changes from the 2008 EM 385-1-1 (and its seven published changes).The EM 385-1-1 manual was designed by USACE, in collaboration with NAVFAC, and provides an overview of the safety requirements on federal projects. The 2014 Edition supersedes the last edition of EM 385-1-1 published in 2008. While many of the requirements in the EM 385-1-1 align with OSHA Standards, some specific requirements …EM 385-1-1 XX Jul 14 3-1 SECTION 3 . Medical and First Aid Requirements . 03.A General. 03.A.01 Prior to the start of work by a contractor and for all USACE locations, arrangements shall be made for medical facilities and personnel to provide prompt attention to injured employees. For work or tasks with a high or extremely high riskNov 1, 2020 · Modified OSHA Form 300 and 300A requirements under Duties of the SSHO. Updated to EM 385-1-1 (NOV 2014) requirements and terms including clarifying requirements for Dive Protection, Fall Protection, Load Handling Equipment, and Electrical. Added Subcontractor Safety requirements for Navy only. In general terms, if the project involves USACE or other federal agencies, EM385 training is mandatory for SSHOs and other key personnel. If the project does not involve USACE or other federal agencies, OSHA 30 training could be sufficient for safety supervisors and managers. However, some government clients may still require EM385 … EM 385-1-1 XX Jul 14 22-4 c. Be readily visible. legible and made from materials that will withstand the elements; d. Include wording that states one of the following: (1) Scaffold is complete and safe to use; (2) Scaffold is incomplete, not ready for use and reasoning, or (3) Scaffold is incomplete and unsafe to use. The EM 385-1-1 Fall Protection End User course provides 8 hours of training based on requirements found in the 2014 Edition of the U.S. Army Corps of Engineers (USACE) Safety and Health Requirements Manual EM 385-1-1. Compliance with EM 385-1-1 guidelines affects all contractors working on government contracts. All contractors and …

Suncoast bank.

Game matcher.

SKU: 61B-001-03. ISBN: 9781599599038. $79.95. Quantity. Add to cart. Mancomm's EM 385-1-1 book describes safety and health requirements for all United States Army Corps of Engineers (USACE) activities and operations. Following this manual will help all contractors working on Department of Defense projects to meet all of the necessary safety ... EM 385-1-1 Training Online. Our EM 385 training keeps you compliant with USACE requirements when working on military projects. Search now to find your course! #1 Trusted USACE Training Provider for 25+ Years. Fast, convenient & flexible courses – 100% online. From your trusted source in online safety training. Designed for government ... 入札公告日に有効な、em 385-1-1 の最新版 (暫定的な変更を含む) を遵守しなければならない。 応札の前に入札者は、hqusace の労働安全衛生ウェブサイト (c. 参照) で、最新の変更点を確 認すべきである。EM 385-1-1 30 Nov 14 5-4 05.B.05 Operations that require handling of harmful materials (e.g., acids, caustics, hot liquids, or creosoted materials) and operations where protection from gases, fumes, and liquids is necessary, shall require the wearing of goggles with cups of soft pliable rubberCICB Senior Instructor Larry Kime introduces us to EM385-1-1. Larry reminds us that contractors on a military installation must be aware of more than the OSHA regulations and ANSI/ASME standards. US Army Corps of Engineers (USACE) EM385-1-1 is a broad range safety standard written into any contract for contractors on a military installation.EM 385-1-1 - Army Corps of Engineers Safety and Health Requirements Documents. Engineering Manual (EM) 385-1-1 is a comprehensive set of safety and health standards required for all operations that services and operations that are subject to OSHA's construction standard (29 CFR 1926.11). Every contractor working on government projects subject to EM 385-1-1 must designate one or more primary SSHOs, depending on the project’s size, complexity, and other factors. The EM 385-1-1 Safety & Health Topics (EM385) Course is intended to partially satisfy SSHO training requirements in accordance with EM 385-1-1 Section 01.A.17.d. Jul 5, 2022 · 入札公告日に有効な、em 385-1-1 の最新版 (暫定的な変更を含む) を遵守しなければならない。 応札の前に入札者は、hqusace の労働安全衛生ウェブサイト (c. 参照) で、最新の変更点を確 認すべきである。 Modified OSHA Form 300 and 300A requirements under Duties of the SSHO. Updated to EM 385-1-1 (NOV 2014) requirements and terms including clarifying requirements for Dive Protection, Fall Protection, Load Handling Equipment, and Electrical. Added Subcontractor Safety requirements for Navy only.EM 385-1-1 - Army Corps of Engineers Safety and Health Requirements Documents. Engineering Manual (EM) 385-1-1 is a comprehensive set of safety and health standards required for all operations that services and operations that are subject to OSHA's construction standard (29 CFR 1926.11).EngineerManuals/EM _385-1-1.pdf . Author: Stafford, Nicholas J CIV USARMY CESAM \(US\) Created Date: 8/22/2018 9:51:37 AM ... ….

Apr 12, 2024 · The revised EM 385-1-1 manual brings several significant changes aimed at enhancing safety and streamlining procedures. Here are some key highlights: Streamlined Structure: Gone are the days of navigating through a maze of information. The new manual is reorganized into 37 focused chapters, each dedicated to a specific safety topic. EM 385-1-1 30 Nov 14 22-4 22.B.06 Anyone involved in erecting, disassembling, moving, operating, using, repairing, maintaining or inspecting a scaffold shall be trained by a CP to recognize any hazards associated with the work in question. Proof of training shall be maintained on site and made available to the GDA upon request. EM 385-1-1 30 Nov 14 33-6 (2) 40-hour training course outline for HTRW operations. 40- hour training courses shall cover the following topics in a manner that is relevant to organizational operations: (a) Names of personnel and alternates responsible for site safety and health; (b) Safety, health and other hazards; EM 385-1-1 XX Jul 14 21-4 . a. be trained appropriately; b. advise and provide guidance for managers, employees and others on all matters pertaining to their Fall Protection …REQUIRED BY EM 385-1-1 2014 Contract Name and Number: [ProjectName] [ProjectNumber] Contractor/Subcontractor: [CompanyName] Government Inspector: Location: Contractor Inspector: Date: NOTE: The following plans should be on site and accessible to employees. The expected answer should be yes to all applicable plans.My Training. This is your training dashboard. From here you can see at a glance which courses you are enrolled upon and progress made. If you completed a course you will be able to view and reprint your certificate from here. Scroll down to view your learning transcript – this transcript will update automatically as progess is made.The Safety and Health Requirement Manual, EM 385-1-1, is now available in an app powered by U.S. Army Corps of Engineers (USACE), and the Far East District (FED) is taking full advantage of it.Sobre. Fundada em 07/06/2022, a empresa T.i. Arquitetura LTDA de CNPJ 46.690.385/0001-67, está localizada na cidade de Gravataí no estado Rio Grande do Sul. Sua área de atuação está atrelada a atividade/CNAE principal 71.11-1-00 - Serviços de arquitetura, conforme informações da Receita Federal. No momento sua situação é Ativa.período, a produção agrícola aumentou em 385% enquanto a área agrícola aumentou somente 32%. Este processo de transformação da agropecuária não é fruto do acaso. Ele é o resultado de décadas de inovação e desenvolvimento de uma agricultura adaptada aos trópicos, com contínuos ganhos de produtividade e intensificação da ...5) Temporary Facilities. 6) Personal Protective and Safety Equipment. 7) Toxic Agents & Environments. View More Module. Price: $49.99. Add To Cart. Best Price Online EM 385 Training, Access 24/7 On All Devices. Easy To Take, Money Back Guarante. Em385, EM 385-1-1 XX Jul 14 Q-1 APPENDIX Q . Definitions . This appendix defines the following terms for the purposes of this manual. Abrasive blasting: the forcible application of an abrasive to a surface by pneumatic pressure, hydraulic pressure, or centrifugal force. Absorbed dose: energy imparted to matter by ionizing radiation per unit mass of, EM 385-1-1 (including interim changes) that is in effect on the date of solicitation. Prior to making an offer, bidders should check the HQUSACE Safety and Occupational Health web site (see paragraph c) for the latest changes. No separate payment will be made for compliance with this paragraph or for compliance with other safety, APP DOWNLOADS for EM 385-1-1. The U.S. Army Corps of Engineers has proudly maintained the EM 385-1-1 (USACE Safety and Health Requirements Manual) for over 75 years. It is now available on both iOS and Android platforms for easier referral, especially in field environments where quick reference is often needed. You can click on either link ... , EM 385-1-1 XX Jul 14 14-4 e. All hoist way entrances shall be protected by substantial gates or bars that shall guard the full width of the landing entrance. Gates shall be not less than 66 in (167.6 cm) in height, with a maximum under clearance of 2 in (5 cm), and shall be located not more than 4 in (10 cm) from the hoist way line., 8-Hour EM 385-1-1 Refresher Training. The 8-Hour EM 385-1-1 online refresher course is designed to keep Site Safety Health Officers (SSHOs), military contractors and government employees compliant with annual refresher training requirements from the U.S. Army Corps of Engineers. $99. , EM 385-1-1 (including interim changes) that is in effect on the date of solicitation. Prior to making an offer, bidders should check the HQUSACE Safety and Occupational Health web site (see paragraph c) for the latest changes. No separate payment will be made for compliance with this paragraph or for compliance with other safety, CICB’s four-day program for US Army Corps of Engineers (USACE) EM 385-1-1 Training has been developed with the objectives to assist USACE personnel, contractors or management and employers achieve and maintain compliance with this comprehensive standard. This manual applies to Headquarters, US Army Corps of Engineers elements, …, EM 385-1-1 30 Nov 14 27-3 d. Plumbing-up guys shall be removed only under the supervision of a Competent Person (CP). e. Measures shall be taken to prevent unrolled wire mesh from recoiling. 27.B. 03 Post-tensioning operations. a. No employee (except those essential to the post-tensioning operations) shall be, EM 385-1-1 15 Jul 14 A-1 APPENDIX A Minimum Basic Outline for Accident Prevention Plans 1. Accident Prevention Plan (APP) - General. An APP is a safety and health policy and program document that is contract- or job- specific. It is an integral part of the planning process. > See Section 01 and 01.A.12. a. , Sobre. Fundada em 07/06/2022, a empresa T.i. Arquitetura LTDA de CNPJ 46.690.385/0001-67, está localizada na cidade de Gravataí no estado Rio Grande do Sul. Sua área de atuação está atrelada a atividade/CNAE principal 71.11-1-00 - Serviços de arquitetura, conforme informações da Receita Federal. No momento sua situação é Ativa., in conjunction with ER 385-1-80 and EM 385-1-1. Contractor requirements concerning ionizing and non-ionizing radiation protection issues are contained in EM 385-1-1. 1-3. Distribution Statement. Approved for public release; distribution is unlimited. 1-4. References. Appendix A contains a list of references used in this manual. 1-5. Policy. a. , This course meets and/or exceeds the requirements of the UFGS (2010) 01 35 26 for Key Contractor Personnel. Course Length: Four 10-Hour Days. OSHA 30 Certification is included in this course. Southern California EM385-1-1 40 Hour Construction Safety Course with OSHA 30 Call us to schedule: (800) 969-3228., EM 385-1-1 XX Jul 14 1-2 01.A.07 SOH Bulletin Board. The Contractor or USACE Project shall erect and maintain a SOH bulletin board in a commonly accessed area in clear view of the on-site workers. The bulletin board shall be continually maintained and updated and placed in a location that is protected against the elements and unauthorized removal. , The EM-385-1-1 manual is vital in getting and maintaining work on government contracts. It includes all safety and health requirements for all Corps of Engineers activities and operations, including Naval Facilities Engineering Command (NAVFAC) construction and Department of Defense projects. This edition replaces the …, We would like to show you a description here but the site won’t allow us., EM 385-1-1 forms and informational material for reference and review. USACE EM 385-1-1 2014 PDF, USACE Coy Fax Form, EM 385-1-1 book purchase, etc., Those who complete EM 385-1-1 Fall Protection training have the knowledge and skills to assess worksites, develop safe work plans and identify and correct any problems on-site. The training includes building a Fall Protection and Prevention Plan, which is a high-level plan put in place before projects begin, and acts as a roadmap for workers to follow., EM 385-1-1 15 Jul 14 A-1 APPENDIX A Minimum Basic Outline for Accident Prevention Plans 1. Accident Prevention Plan (APP) - General. An APP is a safety and health policy and program document that is contract- or job- specific. It is an integral part of the planning process. > See Section 01 and 01.A.12. a. , EM 385-1-1 Course Overview This 40-Hour EM 385-1-1 course is crucial for maintaining a safe and efficient work environment on military jobsites. We provide information relative to the 2014 US Army Corps Safety and Health Requirements Manual, EM385-1-1 and pertinent Occupational Safety and Health Administration (OSHA) construction standards. , Apr 12, 2024 · The revised EM 385-1-1 manual brings several significant changes aimed at enhancing safety and streamlining procedures. Here are some key highlights: Streamlined Structure: Gone are the days of navigating through a maze of information. The new manual is reorganized into 37 focused chapters, each dedicated to a specific safety topic. , This manual applies to Headquarters, US Army Corps of Engineers (HQUSACE) elements, major subordinate commands, districts, centers, laboratories, and field operating …, EM 385-1-1 XX Jul 14 21-4 . a. be trained appropriately; b. advise and provide guidance for managers, employees and others on all matters pertaining to their Fall Protection …, EM 385-1-1 30 Nov 14 29-2 29.A.03 All persons working with explosives shall be in good physical condition and be able to understand and give written and verbal orders. , OSHAcademy 40-Hour EM 385-1-1 (2024) Provides awareness of the EM385-1-1 (2024) standards as required by USACE. Convenient online training at your own pace. Access course materials for FREE. No up-front fees or costs! Purchase a PDF certificate upon completion. $199., We’ve been trusted by millions of learners to provide their regulatory-approved training. You get simple to follow course content that you can access anytime, anywhere. We're here for you with online chat and toll-free phone support. You’re in good hands. We’ve been in business for over 25 years. Shop for site safety and health officer ..., This 16-Hour EM 385-1-1 course is an introductory program, covering the regulations and directives outlined in the 2024 EM 385-1-1 manual. Tailored for military contractors, the training ensures compliance with Army Corps of Engineers Contractor Safety and Health Requirements. Topics include the identification of Site Health and Safety Officers ..., COE EM 385-1-1, para 01.A.13.b: Work will not begin until the AHA for the work activity has been accepted by the Government Designated Authority (GDA) and discussed with all engaged in the activity, including the Contractor, subcontractor(s), and Government on -site representative at preparatory and initial control phase meetings., 入札公告日に有効な、em 385-1-1 の最新版 (暫定的な変更を含む) を遵守しなければならない。 応札の前に入札者は、hqusace の労働安全衛生ウェブサイト (c. 参照) で、最新の変更点を確 認すべきである。, EM 385-1-1 30 Nov 14 1-3 b. The current Unified Facilities Guide Specification (UFGS) for Safety and Health in effect on the date of solicitation shall be used in all USACE contract work administered on behalf of the USACE under the provisions of FAR Clause 52.236-13 ., EM 385-1-1 XX Jul 14 18-4 c. Alarms shall operate automatically upon commencement of backward motion. Alarms may be continuous or intermittent (not to exceed 3-second intervals) and shall operate during the entire backward movement. d. Commercial cargo vehicles such as pick-up trucks, utility cargo/tool trucks, and, www.publications.usace.army.mil, EM 385-1-1 Section 25 - Free download as PDF File (.pdf), Text File (.txt) or read online for free. This document provides the table of contents for Section 25 of EM 385-1-1, which covers requirements for excavation and trenching. The section includes general provisions on excavation/trenching plans, soil testing and documentation, protective systems, …, EM 385-1-1 XX Jul 14 10-2 10.A.05 Cable, hoses, and other equipment shall be kept clear of passageways, ladders, and stairways. 10.A.06 Welding and cutting of hazardous materials. a. When welding, cutting, or heating on steel pipelines containing natural gas, …