Adjusting a sporlan txv

Note: The New Hand Expansion Valve plugs and Bonnet Assemblies will not retrofi t to either a prior design hand expansion valve body or to a prior design stop valve. Bulletin No. 82-00B August 2007 Installation, Service and Parts Information R/S Bonnet Design (Typical of 3/4" and 1") Machined Bonnet Bore Packing Nut Carbon PTFE O-Ring Carrier

Adjusting a sporlan txv. Expansion Valve (TXV) - R-410A, 3-Ton, 3/8 in. Inlet, 3/8 in. Outlet. IMPORTANT: Heating, ventilation, air conditioning or refrigeration parts and accessories should only be installed by qualified technicians. Failure to understand and follow the manufacturer's installation and use instructions may result in fire or explosion, electric shock ...

Brazing in a TXV into a HVAC unit. here I show how to perform copper Brazing and how to braze a TXV without burning and destroying it. I use brazing rods and...

2 / BULLETIN 500-10-HC-CR. The selections are based on load and operating conditions provided by Heatcraft Inc. All selections are based on condensing pressures of 175 psig (R-22), 200 psig (R-404A and R-507), and 10 degree liquid subcooling. Externally equalized valves are used with coils having refrigerant distributors.These valves have a removable 100 mesh strainer as a standard feature. These valves are designed for small refrigeration systems such as refrigerated cases, coolers, and freezers where space is limited and an external adjustment is desired. Overall height: 3.76" Element size: 43; Capillary length: 30"In this episode of the HVACR Distillery, Jamie shares some lesser-known tips on how to install, maintain, and set superheat on a TXV, or Thermostatic Expansi...Sporlan - 168198 - TXV SBQE BODY 3/8" x 1/2" x 1/4" ODF External Equalizer Angle. Item: SBQEBODY381214ODF. MFG: 168198. loading availability. Loading price. / EA.Bulletin 210-40-4 - Sporlan Field Conversion of the Thermostatic Expansion Valves with Replaceable Thermostatic Elements: Bulletin 210-60 - Sporlan Thermostatic Expansion Valves Identification: SD-14 - Sporlan Thermostatic Expansion Valves Installation, Field Service, and Assembly: SD-289 - Sporlan TEV Installation and Instructions

With the expansion valve at the Sporlan factory setting, or at a manufacturer's predetermined setpoint, and under the actual minimum load condition, the evaporator pressure regulating valve should be adjusted to the desired setting. Finally, if necessary, the thermostatic expansion valve or valves can be adjusted to the desired superheat setting7__GJE-1-1/2-C 3X4 SAE 5' __7. Sporlan Type G thermostatic expansion valves are designed for use on Air Conditioning and Refrigeration units. They regulate refrigerant flow by maintaining a nearly constant superheat at the evaporator outlet.<br/><br/>.This Parker Sporlan webinar training module will discuss how to properly select solenoid valves to ensure dependable operation in refrigerant flow system. F...Expansion valve, balanced port, R22 family, external equalizer, 10 tons, 5/8" ODF inlet x 7/8" ODF outlet, C charge (medium temp) Quantity. Add to Cart. Nearby Stock. ... Sporlan type O valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable and the inlet connection has a ...Expansion valve, balanced port, R22 family, external equalizer, 10 tons, 5/8" ODF inlet x 7/8" ODF outlet, C charge (medium temp) Quantity. Add to Cart. Nearby Stock. ... Sporlan type O valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable and the inlet connection has a ...Sporlan - 611046 - Expansion Valve (TXV) with Bleed Port, Check Valve, R-410A. Item: RHE611046 . MFG: 611046 . loading availability. Loading price / EA. Skip to. Description; Features and Specification; Description Sporlan 611046 - Expansion Valve (TXV) with Bleed Port, Check Valve, R-410A ...Mar 2, 2017 · So, adjusting the TXV is NOT the way to deal with low suction pressure. You only adjust a TXV to make it reach the target superheat. Also, see if you’re measuring superheat inside or outside; the outside superheat may give you an inaccurate reading due to the likelihood of higher ambient temperatures. Not all expansion valves are adjustable.

Defining superheat "hunting". Superheat hunting is a cyclical fluctuation in suction superheat due to a varying refrigerant flow rate in the system. Superheat hunting is the result of the expansion valve (see TEV illustration below) excessively opening and closing in an attempt to maintain a constant operating condition.Welcome to Parker's Sporlan Division. Parker Sporlan is solving HVAC and refrigeration industry challenges by providing innovative solutions which aid technicians in diagnosing and repairing systems quickly and accurately. Sporlan also offers a range of components and systems that increase energy efficiency and reduce emissions, helping to ...Lots of businesses use techniques like SEO and social media marketing. But they don’t all use them in the same way. Lots of businesses use techniques like SEO and social media mark...Thermostatic Expansion Valve - Sporlan - Type SBF. Sporlan Type SBF thermostatic expansion valves are designed for use on Air Conditioning and Refrigeration units. They regulate refrigerant flow by maintaining a nearly constant superheat at the evaporator outlet.MAXIMUM PRESSURE (PSI): 700. ELEMENT: 45. The Sporlan Type R-ER-SR, and RC balance ported thermostatic expansion valves have a brass bar stock body. The R valve has flare connections, the ER has extended ODF connection and SR has extended ODF connections with forged inlet and replaceable strainer. Type RC valve contains an internal check valve.

Coeur d'alene pawn shops.

Sep 18, 2017 · This overview walks you through everything you need to know about safely and accurately adjusting the superheat on Danfoss TR6 thermostatic expansion valves.... Expansion valve, balanced port, R22 family, external equalizer, 1-1/2 ton, 3/8" MFL inlet x 1/2" MFL outlet, C charge (medium temp), 169378. Quantity. Add to Cart. Nearby Stock. Add to Job List Compare Email a friend. View Catalog Page . Product Details. Vendor Name: Sporlan URI Part Number: RVE1-1/2C Vendor Part Number: 169378 Shipping Weight ...Desuperheating Thermostatic Expansion Valve - When the desuperheating TEV is used in conjunction with the bypass valve, piping the two valves to get good mixing before reaching the TEV bulb location is vital. This can be accom-plished several ways but the simplest is to tee the liquid-vapor mixture from the TEV and the hot gas from the DBVSporlan – Turn all the way in clockwise, and then go out 4 ½ turns counterclockwise. Let it set and equalize, and then check after 15 mins. The goal is a 6-12-degree superheat. When adjusting, make minor adjustments, and then let it sit and wait for adjustments to show. —Clayton. #Rack refrigeration #TXV.Lots of businesses use techniques like SEO and social media marketing. But they don’t all use them in the same way. Lots of businesses use techniques like SEO and social media mark...Spanner end tightens packing nut around super heat adjustment stem. 1/8″ square end adjusts Sporlan solenoid valves with manual lift stems as on Series B6 and E6 through MA 50. Also 3/16″ square at same end for expansion valves. Made in the USA. Sporlan Solenoid Valve Wrench - Spanner end tightens packing nut around superheat adjustment ...

Sporlan TEV Adjustment I installed a Sporlan TEV today that was adjustable. This particular installation was for an A/C unit, but being most Residential A/C TEVs are not adjustable, I thought it a waste of time to ask the following questions. ... Question 1 - the power head is the only opening force on the expansion valve . If it fails …Since this is a package unit, I'd like to adjust the TXV to bring that down and help with the low pressure. Am I correct in. Refrigeration-Engineer.com forums > REFRIGERATION DIVISIONS > Air ... View Full Version : Adjusting Sporlan TXV for SH. Ryan@PMS. 02-03-2009, 10:15 PM.Depending on your car, turning off the ignition or disconnecting the battery may involve turning off the ignition. Step 3. Locate the TXV and Identify any Visible Signs of Restriction. To locate the TXV, you will need to follow the refrigerant lines from the compressor to the evaporator.Ritchie Engineering Co., Inc. / YELLOW JACKET Yellow Jacket 60617 Sporlan Valve Wrench . Brand: Ritchie Engineering Co., Inc. / YELLOW JACKET. 4.4 out of 5 stars 17. $46.52 $ 46. 52liquid-vapor mixture from the expansion valve. This ensures a dry vapor reaching the compressor. Oil return from the evaporator is also improved since the velocity in the evaporator is kept high by the hot gas. Sporlan 1650R Series Distributor or ASC –Two refrig-erant distribution methods are available to introduce hot gas in this manner: 1.I have only had to adjust the SH on several TXV mostly on the new refrigerants used now. The TXV is very reliable device. I have a buddy that works for sporlan and he always tells me that adjusting the SH is a last thing to do. Reply . 06-04-2011, 01:08 AM #20. OntimeJ. View Profile View Forum Posts View Forum Threads New …The thermostatic expansion valve (TEV) controls the flow of liquid refrigerant entering the direct expansion (DX) evaporator by maintaining a constant superheat of the refrigerant vapor at the outlet ... Sporlan Pulse Width Modulation valves are rated at 100% duty cycle with no reserve capacity. The 50% ... Does the valve have a superheat ...Bulletin 210-60 - Sporlan Thermostatic Expansion Valves Identification SD-14 - Sporlan Thermostatic Expansion Valves Installation, Field Service, and Assembly SD-289 - Sporlan TEV Installation and Instructions SD-414 - Sporlan FX TEV Installation and Instructions Sporlan Replacement Parts - Bulletin 122 Product Demos & Tutorials

THERMOSTATIC EXPANSION VALVE CROSS REFERENCE INTERCHANGEABLE ORIFICE Nominal Capacity (tons) Connec-tion ALCO SPORLAN PARKER VIRGINIA SINGER DANFOSS TOTALINE REPLACEMENT Type Orifice P/N P/N Body Orifice Conn. lnxout (in.) R-12 INT. PRESSURE EQUALIZING 1/3 flare HC1/4FW RCD1/2FW NIF1/4 FF1/4 GF1/4 DF1/4 RA1/4FA 223FA1/4 228FA1/4 TF 2 01

The ONLY way to verify operation of a TEV is to check the superheat and adjust it to your need. 10 degrees might be fine for AC purposes, but I need things quite a bit cooler than that for refrigeration sometimes. Reply. 10-21-2013, 06:42 AM #11.2 / BULLETIN 500-10-HC-CR. The selections are based on load and operating conditions provided by Heatcraft Inc. All selections are based on condensing pressures of 175 psig (R-22), 200 psig (R-404A and R-507), and 10 degree liquid subcooling. Externally equalized valves are used with coils having refrigerant distributors.DAE5L - Expansion valve, standard port, NH3, external equalizer, 5 tons, 1/2" FPT inlet x 1/2" FPT outlet flanged, L charge (liquid) ... Sporlan type D valve is a gray cast bronze body, externally adjustable valve available with FPT flange connections. The thermostatic element is replaceable and all internal parts are replaceable.An internal equalizer expansion valve, also known as an internal equalizer TXV, doesn't have an electronic part to adjust. It uses fully mechanical-based adjustment by three pressure types from the feeler bulb, internal equalizer port, and spring rod pressure to balance various forces for precise control. It is designed with internal ...Satellite television is a terrific way to get the channels you want at a price you can afford. But what do you do if your satellite goes out of alignment? A poorly aligned dish can...To reduce the superheat, turn the adjusting stem COUNTER-CLOCKWISE.Toincreasethesuperheat,turntheadjustingstem Should a Sporlan thermostatic expansion valve (TEV) be adjusted after installation? 52° F C O N V E R T E D T O T E M P . OBTAIN SUCTION PRESSURE . . . 69 PSIG (at bulb) 52 ° 40° 12 ° SUPERHEAT Temperature here reads EXAMPLE ...ERVE-1-C 1/4" x 1/2" ODF Thermal Expansion Valve w/ 60" Capillary (1 Ton) SKU: 169185. Sporlan. Sporlan Thermal Expansion Valves (TXVs) are available in a variety of heat pumps, air conditioning, and refrigeration applications. Here you can find a Thermostatic Expansion Valve for nearly any HVAC job.

Florence county sc bookings and releases.

Gloria bell karl malone pictures.

Sporlan Division Products can and do fail without warning for many rea-sons. Design all systems and equipment in a fail­safe mode, so that fail­ ure of these products and related accessories will not endanger persons or property. Pressure Rating: The maximum internal pressure of the Y1037, Y1210 and Y1244 valves is 500 psig (34 bar).Evaporator Pressure Regulation. Sporlan Evaporator designed to provide Pressure an economical Regulating valves (EPRs) are means of accurately maintaining varying evaporator evaporator loads. pressure The primary and function temperature of an under EPR is to prevent the evaporator pressure predetermined value temperature is or setting.With the expansion valve at the Sporlan factory setting, or at a manufacturer's predetermined setpoint, and under the actual minimum load condition, the evaporator pressure regulating valve should be adjusted to the desired setting. Finally, if necessary, the thermostatic expansion valve or valves can be adjusted to the desired superheat setting1. Before disassembling the TEV, be sure the refrigerant pressure in the system has been reduced to a safe level (0 psig). 2. Remove the non-adjustable bottom cap and spring …Sporlan TEV: 1. Determine the liquid temperature of the refrigerant entering the valve. The TEV capacity tables on pages 4 to 8 are based on a liquid temperature of 100°F for …9__N/A __9. 10__KT-43-VNB 5' (1.5M) ELEMENT __10. Sporlan Type Q thermostatic expansion valves are for use on Air Conditioning & Refrigeration units. They have a replaceable cartridge design. They regulate refrigerant flow by maintaining a nearly constant superheat at the evaporator outlet.Outlet Connection Size: 1-1/8" ODF inch. Maximum Operating Pressure: 31 bar, 450 psi. Equalizer Connection Type: Externally Equalized. Capillary Tube Length: 1.524 m, 5' inch. Strainer Type:Connect the Electric Expansion Valve (EEV) wires to terminals 5, 6, 7, and 8. ... Sporlan Superheat Control Installation and Operation Manual ... and download Bulletin 100-50-5.1 3. OPERATION For further system tuning, adjust parameter setpoints as described below and in Bulletin 100-50-5.1. 1. Enter the Parameter Menu: Hold down the SELECT ... ….

The adjusted r-square is a standardized indicator of r-square, adjusting for the number of predictor variables. This shows the standardized variance of the independent variables on...Thermostatic Expansion Valve - Sporlan - Type SBF. Sporlan Type SBF thermostatic expansion valves are designed for use on Air Conditioning and Refrigeration units. They regulate refrigerant flow by maintaining a nearly constant superheat at the evaporator outlet.TXV Selection for Evap Coils AA14-42B Russell 4200 10° All-Temp 25° 1/2 SAE AFA 1/2 HC HF 1/2 HC AFA 1/4 RC HF 1/4 SC AFA 1/4 MC HF 1/4 MC AA14-42B Russell 5000 12° All-Temp 25° 1/2 SAE AFAE 1/2 HC HFE 1/2 HC AFA 1/2 RC HF 1/2 SC AFAE 1/2 MC HFE 1/2 MCTo reduce the superheat, turn the adjusting stem COUNTER-CLOCKWISE.Toincreasethesuperheat,turntheadjustingstem Should a Sporlan thermostatic expansion valve (TEV) be adjusted after installation? 52° F C O N V E R T E D T O T E M P . OBTAIN SUCTION PRESSURE . . . 69 PSIG (at bulb) 52 ° 40° 12 ° SUPERHEAT Temperature here reads EXAMPLE ...Allows visual inspection of solder joints. Permits use of a probe wire or air jet to test for plugged circuits at distributor or evaporator coil. FOR USE ON REFRIGERATION and/or AIR CONDITIONING SYSTEMS ONLY Bulletin 20-10, February 2009 supersedes Bulletin 20-10, November 1999 and all prior publications.SBFSEAZ. $ 384.18 View Contractor Pricing. View Inventory. Expansion valve, balanced port, R404A family, external equalizer, 1/2 to 1 ton, 3/8" ODF inlet x 1/2" ODF outlet, Z charge (low temp) Quantity. Add to Cart. Step 4: Measure Initial Superheat. Before making any adjustments to the TXV, you’ll need to establish a baseline by measuring the existing superheat. Attach a temperature probe to the suction line near the evaporator coil. Note down the temperature reading. See also Compressor Short Cycling: 6 Proven Solutions. Are you in search of a good night’s sleep? Look no further than adjustable beds. With their customizable features and therapeutic benefits, these beds have become increasingly popu... Adjusting a sporlan txv, Keeping your brakes working properly is an important part of vehicle maintenance. If your vehicle has drum brakes, you need to adjust them periodically to prevent them from draggin..., Dogs can experience constipation from time to time, just like humans. It can be uncomfortable for your furry friend and may cause them distress. However, with a few lifestyle adjus..., Sporlan - 168015 - TXV SQE BODY 3/8" x 1/2" x 1/4"ODF External Equalizer Angle . Parker Sporlan . Sporlan - 168015 - TXV SQE BODY 3/8" x 1/2" x 1/4"ODF External Equalizer Angle ... TXV/TEV - Thermostatic Expansion Valve: Outlet Connection Size: 1/2" ODF: Package Height: 6.25: Package Length: 14.5: Package Weight: 21.56: Package Width: 13: Prop ..., I've got a sporlan INE-4-GA-B10 expansion valve that i need to adjust the superheat on. The system is running with about 3C superheat at the moment which i feel is a bit too low, i suspect this is due to the valve being R407c and the system is on R22.... Anyway, started to undo what i think is the adjusting stem cap to be met with a gush of leaking liquid, waited a bit just incase it was a bit ..., In this video I swap out a power head on a TXV without recovering the refrigerant. #airconditioner #hvaclife #hvactechnician #hvacguy #acrepair #hvac #hvacin..., People with adjustment disorder experience a severe response to a stressful event or big change, but the condition is highly treatable. Divorce, illness, or a new job can spark an ..., EFS1C. Expansion valve, standard port, R404A family, internal equalizer, 1 ton, 3/8" ODF inlet x 1/2" ODF outlet, C charge (medium temp) Connection Size Inlet (In.): Connection Size Outlet (In.): Overall Height (In.): WARNING: This product can expose you to chemicals including Lead, which are known to the State of California to cause cancer and ..., The TXV cannot be adjusted open or closed, it is a modulating valve. Turning the adjustment stem clockwise will only increase spring pressure causing a higher superheat. Turning the adjustment stem counterclockwise will decrease spring pressure reducing superheat. When an operating refrigeration system stops working, the TXV may have lost its ..., The expansion valve body is about two (2) inches long. Look between the arrows. You must have the MODEL number of the coil to get the right valve. See the "NOTE" below. NOTE: RCFA-XX2417AU (example of TXV type) XX is AU = AC only (upflow or downflow, cased) XX is HU = AC or HP (upflow or downflow, uncased) XX is HM = AC or HP (multi ..., These valves have a removable 100 mesh strainer as a standard feature. These valves are designed for small refrigeration systems such as refrigerated cases, coolers, and freezers where space is limited and an external adjustment is desired. Overall height: 3.76" Element size: 43; Capillary length: 30" Connection: ODF inlet x ODF outlet, Use the correction factor for 100°F liquid temperature and the capacities at 40°F evaporator temperature to determine ARI standard capacity ratings. Example: The capacity of a (S)ORIT-PI-3 using R-401A, evaporator temperature of 20°F, 2 psi pressure drop across the valve, and a liquid temperature of 40°F, is equal to (3.90 x 1.08) 4.2 tons., A thermostatic expansion valve (TXV) (see Figure 1) is a refrigeration and air conditioning throttling device that controls the amount of refrigerant liquid injected into a system's evaporator—based on the evaporator outlet temperature and pressure—called the superheat. Figure 2 shows the different phases and pressures the refrigerant ..., First, measure the superheat right at the evaporator outlet in the same general location as the TXV bulb and equalizer. In most cases, the superheat at that point should be 5-10 degrees, but refer to the manufacturer's specs when in doubt. In some cases, you will not have a pressure port at the evaporator, so you must rely on a pressure reading ..., Sporlan TEV: 1. Determine the liquid temperature of the refrigerant entering the valve. The TEV capacity tables on pages 4 to 8 are based on a liquid temperature of 100°F for R-22, R-134a, R-401A, R-402A, R-404A, R-407C, R-408A, R-409A, R-410A, and R-507. For other liquid temperatures, apply the correction , Danfoss TXV Vs. Alco TXV. This is the second time that happen: 1.-. In small Walkin cooler - R134a (20F) first I installed a Danfoss TXV with MOP element (capacity, temperatura, etc.) and because it keep closing and staying to long close I could not reach the temperature. So I change for the same (not MOP) Alco TXV and Bingo everything is OK ..., One thing to notice is that Hillphoenix has added a note to their NRG case cut sheets saying that the evaporator temperature cannot be more than 4* lower than the recommended value. This is a fairly new CYA note. Setting the higher 58# pressure may help with icing and get more accurate superheat values., The Sporlan Type V thermostatic expansion valves have a cast bronze body, dual port semi-balanced design, flange connections, and inlet strainer. They are available with adjustable superheat, long lasting replaceable power element and accessible internal parts. Each valve is factory tested to ensure positive leak-free performance., The TXV cannot be adjusted open or closed, it is a modulating valve. Turning the adjustment stem clockwise will only increase spring pressure causing a higher superheat. Turning the adjustment stem counterclockwise will decrease spring pressure reducing superheat. When an operating refrigeration system stops working, the TXV may have lost its ... , • The intended design life of the Electric Expansion Valve is 15 years, providing that the valve is installed and operated within the design intent, and the system is free from contaminants. ... • Sporlan is not responsible for any damage which may be caused by misuse or by installation of parts, accessories or controls which are not on the ..., Welcome to Parker Sporlan Chillskills Online Training & Learning. For over 85 years Sporlan has remained committed to strengthening the HVACR industry through education. We are excited to continue our tradition of providing educational HVACR information and training to the industry. Learn from our Parker Sporlan Specialist Training, Wholesaler ... , Note: The New Hand Expansion Valve plugs and Bonnet Assemblies will not retrofi t to either a prior design hand expansion valve body or to a prior design stop valve. Bulletin No. 82-00B August 2007 Installation, Service and Parts Information R/S Bonnet Design (Typical of 3/4" and 1") Machined Bonnet Bore Packing Nut Carbon PTFE O-Ring Carrier, Standard bleed port sizes are: 5%, 10%, 15%, 20%, 30%, and 40%. Bleed ports are designated by the percentage they increase nominal valve capacity at 40°F evaporator temper-ature. For example, a 2 ton TEV with a 30% bleed will have the capacity of: 2 x 1.3 = 2.6 tons. Refer to Page 17 for Ordering instructions., Sporlan type O valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable and the inlet connection has a permanent 12 mesh strainer. This valve type features a balanced port construction and is designed for both air conditioning and refrigeration applications., Parker Hannifin Corp. (Sporlan) 30" Capillary Tube, Thermostatic Expansion Valve Element for Refrigerant, Air Conditioner. Most Sporlan thermostatic expansion valves can be completely disassembled in the field allowing access to all internal parts. Sporlan offers a wide array of high quality replacement parts and long lasting replaceable power ..., Sep 18, 2017 · This overview walks you through everything you need to know about safely and accurately adjusting the superheat on Danfoss TR6 thermostatic expansion valves.... , Welcome to Parker Sporlan Chillskills Online Training & Learning. For over 85 years Sporlan has remained committed to strengthening the HVACR industry through education. We are excited to continue our tradition of providing educational HVACR information and training to the industry. Learn from our Parker Sporlan Specialist Training, Wholesaler ..., safety and cleanliness must be a priority. Use of an upstream Sporlan filter-drier is highly recom-mended to prevent contamination of the expansion valve. 1. Properly reduce system pressure to atmospheric pressure using accepted industry guide-lines. 2. Choose an installation location that is easily accessible, and minimizes external contami-, Sporlan txv pdf Txv thermostatic sporlan tzsupplies 1305 Sporlan ove cp100 txv spareparts. Parts One Store | TXV, SPORLAN MECHANICAL. Sporlan controls 168788 erze-3-ga r410a 3 ton txv-168788 Txv sporlan sve-10-c 5/8" r22 Parts one store, One thing to notice is that Hillphoenix has added a note to their NRG case cut sheets saying that the evaporator temperature cannot be more than 4* lower than the recommended value. This is a fairly new CYA note. Setting the higher 58# pressure may help with icing and get more accurate superheat values. , This is at the bottom of a SPORLAN TXV. This is how you adjust superheat. Turn it in, to RAISE or turn it out, to LOWER superheat. They are prone to leaks quite frequently as shown by the oil drip. NOTE: Notice how there is oil dripping from the bottom of the TXV, this bottom packing nut can be tightened up by using a sporlan tool or a special ..., Page 2 / BULLETIN 90-21. When adjusting both evaporator pressure regulators and ther-mostatic expansion valves, the following procedure is recom-mended: With the expansion valve at the Sporlan factory setting or at a manufacturer’s predetermined set point, and under the actual minimum load condition, the evaporator pressure regulator should ..., Sporlan Solenoid Valves are either copper or brass. Any of the commonly used types of solder are satisfactory with these materials. Regardless of the type of solder used, it is important to avoid overheating the valve. The tip of the soldering torch should be large enough to avoid prolonged heating of the connection during the soldering operation., Sporlan constructed the NX valve with a single, balance-ported pushrod which is specifically designed to help flush out any solid debris build-up. The bleed port feature allows the system refrigerant to bypass the pin and port. System designers can utilize this feature to alter system performance for a variety of reasons. Bleed port options